Split Pressurized Solar Systems
Elevate Your Energy Efficiency with DELAN Premium Solutions
DELAN designs and manufactures split pressurized solar water heating systems engineered for long-term deployment in commercial, residential, and industrial environments.
Unlike integrated solar water heaters, this system separates:
- Roof-mounted solar collector array
- Indoor pressurized storage tank system
This architecture is widely adopted in modern EPC and real estate development projects because it solves three critical engineering challenges:
- Reducing structural load on rooftops
- Ensuring stable pressurized hot water delivery under multi-point usage
- Improving long-term maintenance accessibility for large-scale systems
Our systems are designed for project-based engineering applications, not consumer-level installations, and are optimized for continuous operation in demanding environments.
-
Split Pressurized Solar System For Hotel ProjectsRead More
The Split Pressurized Solar Water System is an engineered centralized hot water solution designed for hotels, resorts, hospitals, and commercial buildings requiring stable 24-hour hot water supply.
-
1000L Centralized Split Pressurized Solar Water Supply Sy...Read More
The 1000L Centralized Split Pressurized Solar Water Heating System is designed for continuous commercial hot water applications such as hotels, hospitals, dormitories, and industrial buildings.
-
500L Commercial Split Pressurized Solar Hot Water SystemRead More
The 500L Commercial Split Pressurized Solar Hot Water System is an advanced solar thermal engineering solution designed for continuous commercial hot water supply.
-
Heat Pipe Vacuum Tube Split Pressurized Solar Heating SystemRead More
The Heat Pipe Vacuum Tube Split Pressurized Solar Heating System is a commercial-grade solar thermal solution designed for EPC contractors, developers, and industrial users requiring reliable,
-
High-Efficiency Flat Plate Split Pressurized Solar SystemRead More
A split-type closed-loop solar water heating system designed for reliable domestic hot water supply in residential, hospitality, and commercial buildings. The system is engineered for stable
-
Commercial Split Pressurized Solar Water Heating SystemRead More
Engineered for heavy-duty commercial applications, the Delan Therma split pressurized solar system delivers scalable, zero-emission thermal energy for hotels, hospitals, factories, and schools.
Engineering Design Philosophy
The system design is based on real-world deployment requirements observed across different climate zones and commercial infrastructures.
Key engineering principles include:
- Hydraulic stability under municipal water pressure systems (0.6–6 bar operating environments)
- Freeze protection strategies for sub-zero climates using closed-loop glycol heat transfer systems
- Thermal efficiency optimization through differential temperature (ΔT) control logic
- Material selection based on chloride concentration, water hardness, and corrosion risk
- Modular maintenance architecture to reduce downtime in commercial applications
- System scalability for multi-building and centralized hot water networks
Each configuration is designed through engineering simulation, system load estimation, and field deployment feedback from international project environments.
Collector System Technologies

Heat Pipe Vacuum Tube System (Cold Climate Optimized)
This system is designed for regions with freezing temperatures and seasonal instability.
Technical characteristics:
- Dry heat transfer via sealed copper heat pipes
- No water inside vacuum tubes (freeze-safe structure)
- Independent tube replacement without system shutdown
- Stable performance in sub-zero environments when combined with glycol loops
- Suitable for high-latitude and cold climate EPC projects

U-Pipe Vacuum Tube System (Industrial Efficiency Design)
This configuration is optimized for high-efficiency thermal transfer systems.
Technical characteristics:
- Direct fluid circulation inside copper U-shaped pipes
- Faster thermal response compared to indirect loop systems
- Suitable for industrial pre-heating applications
- Stable operation under continuous load conditions
- Frequently used in process heat recovery systems

Flat Plate Collector System (Architectural Integration Type)
Designed for modern building integration and high solar radiation regions.
Technical characteristics:
- Laser-welded selective coating absorber surface
- Low-profile roof installation design
- High resistance to hail, wind load, and mechanical impact
- Suitable for warm climates and urban construction projects
- Aesthetic integration for architectural facades and rooftops
Technical Specifications
|
Parameter |
Specification |
|
Storage Capacity |
150L – 1000L+ (custom engineered per project) |
|
Operating Pressure |
0.6 MPa standard / up to 1.2 MPa tested |
|
Tank Materials |
SUS304 / SUS316L / enamel-lined steel (application-based selection) |
|
Thermal Insulation |
50–60mm high-density polyurethane foam insulation |
|
Heat Exchanger |
Copper coil system (single or dual loop configurations) |
|
Frost Protection Range |
Down to -35°C (system-dependent configuration) |
|
Manufacturing System |
ISO 9001 certified production process |
Field Engineering Experience

Case Study 01 — Cold Climate Hospitality Project (Eastern Europe)
A large-scale hotel hot water system requiring stable performance under extreme winter conditions.
Application: 120-room hotel central hot water supply
Challenge: Winter temperatures below -20°C with high peak usage demand
Engineering Solution: Heat pipe vacuum tube split system with glycol-assisted closed loop
Outcome: Stable year-round hot water delivery with reduced auxiliary heating dependency
Case Study 02 — Coastal Residential Development Project (Middle East)
Multi-building residential development in high salinity environment.
Application: Centralized hot water supply system for residential complex
Challenge: High chloride water causing corrosion and scaling issues
Engineering Solution: SUS316L stainless steel tank + flat plate collector system
Outcome: Improved corrosion resistance and reduced long-term maintenance cost


Case Study 03 — Industrial Pre-Heating System (Asia Manufacturing Facility)
Continuous thermal load requirement for production line pre-heating.
Application: Boiler pre-heating integration system
Challenge: 24/7 operational thermal demand with high stability requirements
Engineering Solution: U-pipe vacuum tube system integrated into heat recovery loop
Outcome: Reduced fuel consumption and improved energy efficiency stability
DELAN manufacturing systems operate under internationally recognized quality management systems.
Core compliance framework includes:
- ISO 9001 quality management system certification
- CE conformity for mechanical and electrical safety requirements
- Solar Keymark compliance for solar thermal collector systems (model-dependent certification scope)
Third-party verification may involve internationally recognized laboratories such as:
- TÜV Rheinland (system performance and safety testing depending on project specification)
- SGS inspection services (pre-shipment quality verification and documentation support)
Certification scope and documentation can be provided based on project requirements and target market regulations.

Engineering Performance Features
Constant Pressure Hot Water Delivery System
Designed for municipal water supply environments, ensuring stable multi-point hot water output without noticeable pressure fluctuation.
Intelligent ΔT Control System
The system operates based on real-time temperature differential between solar collector and storage tank.Operational logic:
- When ΔT exceeds threshold → circulation pump activates
- When ΔT is insufficient → system remains idle to reduce energy loss
This improves overall solar utilization efficiency and prevents overheating or freezing conditions.
Modular Maintenance Architecture
Heat pipe vacuum tube systems allow individual tube replacement without draining the entire system, minimizing downtime in commercial operations.
Application Scenarios
Commercial Infrastructure Projects
- Hotels and resorts
- Hospitals and healthcare facilities
- Public bathing and wellness centers
- Educational institutions and campuses
Residential Development Projects
- Multi-family apartment complexes
- Luxury villa communities
- High-rise residential buildings
Industrial Applications
- Process pre-heating systems
- Food processing plants
- Textile manufacturing facilities
- Agricultural heating systems
Procurement Process
All systems are designed based on structured engineering input rather than standardized product selection.

Project Data Collection
- Geographic location and climate conditions
- Daily hot water consumption or peak load demand
- Building type and occupancy profile
Thermal System Simulation
- Solar irradiation analysis
- Heat load calculation
- Storage capacity optimization


System Configuration Design
- Collector type selection
- Material specification matching
- Hydraulic system layout design
Engineering Proposal Delivery
- Technical system configuration report
- Thermal performance estimation
- Bill of materials (BOM)
- Commercial quotation for EPC evaluation

Manufacturing Capability & Quality Control
DELAN operates as a direct OEM manufacturer with integrated production capabilities covering:
Vacuum tube manufacturing and sealing
- Pressure tank fabrication and welding
- System assembly and integration
- Hydraulic pressure testing up to 1.2 MPa
- Pre-shipment functional simulation testing
Each system undergoes multi-stage quality verification including:
- Leak detection testing
- Pressure integrity testing
- Thermal performance validation
- System-level operational checks

All systems are packaged for international shipping under industrial-grade export protection standards:
1. Vacuum tubes individually shock-protected with molded foam
2. Tanks secured with reinforced pallet framing
3. Control systems packed in independent crates
4. Spare installation components included (1–2% allowance for operational continuity)
This ensures system integrity during long-distance maritime and land transport conditions.
Warranty & Technical Support
Solar collectors: 5-year limited warranty
Storage tanks: 3-year structural warranty
Control systems: 2-year functional warranty
Technical support includes:
- CAD-based installation layout assistance
- EPC engineering consultation
- Remote troubleshooting support
- Project configuration review and optimization guidance

FAQ
As one of the most professional split pressurized solar systems manufacturers and suppliers in China, we're featured by quality products and competitive price. Please rest assured to wholesale hot sale split pressurized solar systems for sale here from our factory. For customized service and OEM service, contact us now.
commercial solar water system customer base, commercial solar water system opportunities, commercial solar water system technical support









